Clean agent
Clean agents (clean fire extinguishing agents or gaseous fire suppressants) take the form of inert gases that were developed as an environmentally acceptable alternative to halon which is banned in the UK. The gaseous fire suppressant is stored as a pressurised liquid which when discharged into the air turns immediately to gas and can smother a fire. However, some types also discharge as a rapidly evaporating liquid.
These fire suppressants are typically non-corrosive, do not usually damage delicate equipment that is away from the fire and do not usually leave a residue. They work by blocking the combustion reaction while it is occurring.
For these reasons, clean agents are effective on electrical fires; they offer a further benefit in that, unlike water and other liquids, they are formulated to not conduct electricity back to the operator. They are therefore used in wide-bodied commercial aircraft, pharmaceutical and industrial plants, computer rooms, clean rooms, switch rooms, data storage, telecoms areas and art storage areas, to name but a few.
A clean agent suppressant system typically consists of the agent, the container it is stored in, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signalling) and the means to convey the agent to the fire – the piping and dispersion nozzles. Also possible, although less common, is delivering the agent using a solid propellant gas generator that produces either inert or chemically active gas.
Clean agent fire suppressants may be effective in fighting the following European fire classifications:
- Class A: Combustible materials (wood, paper, fabric, most kinds of refuse);
- Class B: Flammable liquids;
- Class C: Flammable gases.
Clean agent fire suppressants can also come in traditional hand-held portable cylinder fire extinguishers, with an activation trigger and nozzle. Or, they may be ceiling-mounted circular discs of 4-10kg capacities with automatic fire detection and activation. Being ceiling mounted they are designed to have a better reach than normal fire extinguishers and are useful in areas where the chances of early fire detection are low. This includes areas where there is little human traffic flow e.g in factories with large storage areas, server rooms and areas such as high chemical stacks that are beyond the range of normal fire extinguishers. A downside is that the red ‘bulb-shaped’ containers can look unsightly although this may not be considered problematic in an industrial setting.
[edit] Halon
In the past, many systems used halon as the base extinguishing agent, considered then as being an ‘environment friendly’ fire extinguishing chemical which produced a halogenated effect. In particular, a variant called HCFC 123 used in some systems was introduced in the 1990s to replace ozone-depleting agents such as Halon 1211 and BCFs.
HCFC 123 was at one time regarded as one of the ‘cleanest’ and ‘most powerful’ extinguishing agents available. According to Gov.UK. HCFC 123 (C2HF3Cl2 Dichlorotrifluoroethane) has an ozone-depleting potential of 0.02. This can be compared to say, HBFC-234 which has an ODP of 7.5. However, HCFC 123 was considered as having very few risks and a relatively small amount was needed to extinguish the fire.
[edit] Related articles on Designing Buildings Wiki
- Automatic fire sprinkler systems: A good practice guide.
- Costs of water automatic sprinkler systems.
- Design benefits of automatic sprinkler systems granted under approved document B.
- Drenchers.
- Fire detection and alarm system.
- Fire detector.
- Fire in buildings.
- Fire protection engineering.
- Fire retardant.
- Fire safety design.
- Sprinkler systems explained: A guide to sprinkler installation standards and rules.
- The cost efficiency of different combinations of fire protection measures.
- The impact of automatic sprinklers on building design.
Featured articles and news
A case study and a warning to would-be developers
Creating four dwellings for people to come home to... after half a century of doing this job, why, oh why, is it so difficult?
Reform of the fire engineering profession
Fire Engineers Advisory Panel: Authoritative Statement, reactions and next steps.
Restoration and renewal of the Palace of Westminster
A complex project of cultural significance from full decant to EMI, opportunities and a potential a way forward.
Apprenticeships and the responsibility we share
Perspectives from the CIOB President as National Apprentice Week comes to a close.
The first line of defence against rain, wind and snow.
Building Safety recap January, 2026
What we missed at the end of last year, and at the start of this...
National Apprenticeship Week 2026, 9-15 Feb
Shining a light on the positive impacts for businesses, their apprentices and the wider economy alike.
Applications and benefits of acoustic flooring
From commercial to retail.
From solid to sprung and ribbed to raised.
Strengthening industry collaboration in Hong Kong
Hong Kong Institute of Construction and The Chartered Institute of Building sign Memorandum of Understanding.
A detailed description from the experts at Cornish Lime.
IHBC planning for growth with corporate plan development
Grow with the Institute by volunteering and CP25 consultation.
Connecting ambition and action for designers and specifiers.
Electrical skills gap deepens as apprenticeship starts fall despite surging demand says ECA.
Built environment bodies deepen joint action on EDI
B.E.Inclusive initiative agree next phase of joint equity, diversity and inclusion (EDI) action plan.
Recognising culture as key to sustainable economic growth
Creative UK Provocation paper: Culture as Growth Infrastructure.
Futurebuild and UK Construction Week London Unite
Creating the UK’s Built Environment Super Event and over 25 other key partnerships.
Welsh and Scottish 2026 elections
Manifestos for the built environment for upcoming same May day elections.
Advancing BIM education with a competency framework
“We don’t need people who can just draw in 3D. We need people who can think in data.”